ECL Prime Western Blotting Det
产品名称: ECL Prime Western Blotting Det
英文名称: ECL Prime Western Blotting Det
产品编号: RPN2232
产品价格: 0
产品产地: 美国
品牌商标: GE
更新时间: null
使用范围: null
- 联系人 :
- 地址 : 上海市宝山区友谊路1506号东智广场1109室
- 邮编 : 201900
- 所在区域 : 上海
- 电话 : 138****5983 点击查看
- 传真 : 点击查看
- 邮箱 : 342786402@qq.com
RPN2124 | ECL PLUS WESTERN BLOTTING REAG |
RPN2125 | ECL BLOCKING AGENT |
PA43009 | ECL PLEX G-A-M IGG, CY3, 150UG |
PA43010 | ECL PLEX G-A-M IGG, CY3, 600UG |
PA45009 | ECL PLEX G-A-M IGG, CY5, 150UG |
PA45010 | ECL PLEX G-A-M IGG, CY5, 600UG |
PA45011 | ECL PLEX G-A-R IGG, CY5, 150UG |
PA45012 | ECL PLEX G-A-R IGG, CY5, 600UG |
RPN998 | ECL PLEX PK:CY3,CY5,HYBOND-ECL |
RPN999 | ECL PLEX PK:CY3,CY5,HYBOND-LFP |
RPN418 | ECL PRIME BLOCKING REAGENT |
RPN1236 | ANTI-GST HRP CONJUGATE - 75 UL |
25-8006-98 | ECLBLOCKING AGENT MODULE |
28-9011-06 | ECL Plex GaR IgG Cy3 150ug |
28-9011-07 | ECL Plex GaR IgG Cy3 600ug |
RPN2232 | ECL Prime Western Blotting Det |
RPN2232SK | ECL Prime Western Blotting Det |
RPN850E | ECL PLEX FL RAINBOWS 120 UL |
RPN851E | ECL PLEX FL RAINBOWS 500 UL |
Amersham ECL Prime Western Blotting Detection Reagent
- High signal intensity and sensitivity allows the use of highly diluted primary and secondary antibodies with no reduction in sensitivity.
- Stable signal allows multiple exposures and makes the reagent suitable for large experimental series, allowing convenient handling time between the end of the experiment and detection.
- Optimized for imaging with ImageQuant LAS series (CCD-based imaging) and compatible with Amersham Hyperfilm.
- Compatible with Rainbow Molecular Weight Markers and Amersham ECL DualVue Western Blotting Markers.
- Optimized for use with Amersham Hybond-P (PVDF) membranes and compatible with Amersham Hybond-ECL (nitrocellulose) membranes.
Amersham ECL Prime is a highly sensitive reagent, characterized by stable signal emission, allowing for the possibility of repeated exposures and making it easier to process several blots in the same experimental run. The high intensity of the emitted signals means that proteins can be detected using highly diluted primary and secondary antibodies, contributing to low background and reducing consumption of reagents.
Amersham ECL Prime consolidates and builds on the benefits of Amersham ECL Plus and Amersham ECL Advance to deliver a detection system that is sensitive, stable, precisely quantitative across a wide dynamic range of protein levels, and conservative in its consumption of expensive antibody reagents.
Amersham ECL Prime Western Blotting Detection Reagent — Technical Specifications
Application | Sensitive Quantitative or Confirmatory Western Blotting |
Recommended Membrane | Hybond-P or Hybond ECL |
Color | Detection reagent 1: Colorless Detection reagent 2: Colorless |
Storage Conditions | 2 - 8°C |
Sensitivity | ~1 pg |
Detection | CCD/Hyperfilm |