SOURCE 15ETH
产品名称: SOURCE 15ETH
英文名称: SOURCE 15ETH
产品编号: 17-0146-01
产品价格: 0
产品产地: 美国
品牌商标: GE
更新时间: null
使用范围: null
- 联系人 :
- 地址 : 上海市宝山区友谊路1506号东智广场1109室
- 邮编 : 201900
- 所在区域 : 上海
- 电话 : 138****5983 点击查看
- 传真 : 点击查看
- 邮箱 : 342786402@qq.com
17-0146-01 | SOURCE 15ETH, 50 ML |
17-0147-01 | SOURCE 15PHE, 50 ML |
17-0148-01 | SOURCE 15ISO, 50 ML |
SOURCE™ Media/RESOURCE™ and Tricorn Columns for HIC
- A range of high-resolution HIC media designed for low- to medium-pressure systems ranging from a peristaltic pump to ÄKTA™design systems and FPLC™ System.
- Ideal for final polishing in a purification process.
- High performance at low back pressure, even with high sample loads of up to 25 mg of protein.
- Features ether (SOURCE™ 15ETH), isopropyl (SOURCE™ 15ISO) and phenyl (SOURCE™ 15PHE) hydrophobic ligands coupled to the 15 μm monodispersed rigid polystyrene/divinylbenzene matrix.
- Prepacked 1-ml RESOURCE™ columns for fast and high-resolution separation are available individually in each of the three matrices or as a set in the RESOURCE™ HIC Test Kit.
- SOURCE 15PHE 4.6/100 PE is a Tricorn™ column designed for high resolution at lab scale and for optimization studies when scaling up.
SOURCE™ Media/RESOURCE™ and Tricorn Columns for HIC
Technical Information
SOURCE™ 15ETH, SOURCE 15ISO, SOURCE 15PHE in media packs and prepacked Tricorn™ and RESOURCE™ columns.
TECHNICAL SPECIFICATIONS | |
SOURCE™ Lab Packs | |
Binding capacity | > 25 mg/ml |
Matrix | Monodisperse polystyrene cross-linked with divinyl benzene |
Particle size | 15 μm |
pH stability | 2-12 (long term), 1-14 (short term) |
Chemical stability | Stable in common buffers, chaotropic agents, detergents, and polar organic solvents. |
Storage | 20% ethanol |
Storage temperature | 4°C to 30°C |
RESOURCE™ Prepacked columns | |
Bed volume | 1 ml |
Bed dimensions | 6.4 × 30 mm |
Max. pressure | 15 bar (1.5 MPa, 217 psi) |
Max. flow rate* | 9.6 ml/min |
SOURCE 4.6/100 PE columns (Tricorn™)† | |
Bed volume | 1.7 ml |
Bed dimensions | 4.6 × 100 mm |
Max. pressure | 40 bar (4 MPa, 580 psi) |
Max. flow rate* | 5 ml/min |
* H2O at 25°C. † Column not suitable for use with ÄKTAprime™ plus system.
|
The figure on the right shows four runs in an optimization series of eight runs to find the optimal running conditions for the purification of protein tyrosine phosphatase on SOURCE 15PHE 4.6/100 PE (Tricorn™). In the optimization series, the concentration of ammonium sulfate, gradient length, pH, flow rate and additives were varied. The activity was measured by p-nitrophenyl phosphate (pNPP) activity assay at 405 nm. In Run 8, the increase in concentration of ammonium sulfate from 1.5 M to 2.0 M and the increase of the length of the gradient resulted in a better separation.
详情请查询以下网址:http://www.gelifesciences.com/aptrix/upp01077.nsf/Content/Products?OpenDocument&moduleid=10335